MCB Distribution Board

Spn Double Door Distribution Board








No.of ways 4,6,8 & 12 ways
Type of installation Surface & Flush mounting
Color/ Finish RAL 7035 Gray (semi Glossy)
Door options Reversible
Door locking Options Sliding Lock
Removable Gland plates Top & Bottom
Protection Level of Distribution Board Advanced
Distribution technique Insulated Busbar
Bus Bar Rating 63A
Incoming Max . 63A
Outgoing Max Individual 63A
Provision for incomer slots 8 Slots
Voltage Rating 240/415v, 3 Phase/ 4 wire
Incoming options Three phase MCB/RCCB/Isolator
Outgoing options single pole MCB up to 63A
Neutral Bar terminal capacity 25mm2, split on both sides
Earthing Bar terminal capacity 25mm2, split on both sides
Ingress protection (IP) Ip43
Rated Insulated Voltage (Ui) 690v
Frequency 50Hz
Dielectric strength 2.5kv
Ambient Temperature 5c to 40c
Distribution Board –Reference standards IS 8623; IS 13032



Tpn Double Door Distribution Board





No.of ways 4,6,8 & 12 ways
Type of installation Surface & Flush mounting
Color/ Finish RAL 7035 Gray (semi Glossy)
Door options Reversible
Door locking Options Sliding Lock
Removable Gland plates Top & Bottom
Protection Level of Distribution Board Advanced
Distribution technique Insulated Busbar
Bus Bar Rating 63A
Incoming Max . 63A
Outgoing Max Individual 63A
Provision for incomer slots 8 Slots
Voltage Rating 240/415v, 3 Phase/ 4 wire
Incoming options Three phase MCB/RCCB/Isolator
Outgoing options single pole MCB up to 63A
Neutral Bar terminal capacity 25mm2, split on both sides
Earthing Bar terminal capacity 25mm2, split on both sides
Ingress protection (IP) Ip43
Rated Insulated Voltage (Ui) 690v
Frequency 50Hz
Dielectric strength 2.5kv
Ambient Temperature 5c to 40c
Distribution Board –Reference standards IS 8623; IS 13032



Technical Features






  • Manufatured as per IS standard – IS 13032 / Is 8623 – 3
  • Manfuatured using special 1mm / 1.2mm thickness CRCA Sheet as per IS 513D grade.
  • Fully powder coated in RAL 7032 Light Gray Color with matt finish and 50-70 micron powder coating Thickness.
  • IP 43 (degree of protection) compliant metal Double door offers added safety.
  • Reversible door facility imparts flexibility at the installation point for customer convenience.
  • Pan assembly for eas of installation of MCBs/RCCBs.
  • Corner shields with smooth edges provide added security to the boards and shield them against
  • physical damages such as bending and peeling of paints etc.
  • provision of installation manual sheet along with the boards enables safe and easy installation of ciruit breakers.



Submersible Pump Controllers

Salient Features and Benefits of starters








  • Conforms to IS/IEC 60947-4- 1 & IEC 60947-4- 1
  • Sheet steel enclosures with IP 54 protection
  • Wide range of relay settings and coil voltages
  • Standardized accessories and spares available

Address

Corporate Office:490/1, Urla Industrial Complex,
Raipur – 493221, Chhattisgarh, India



Phone: Commercial Head -Subodh Shahiwala 8827396151
E-mail: [email protected]